Skip to main content

INOGENI

PTZOptics Voice Tracking supports two INOGENI switchers:

  • INOGENI CAM230
  • INOGENI IP2USB

The INOGENI CAM230 is a hardware USB/IP capture and switching device that supports a REST API for automated input switching.

The INOGENI IP2USB is a hardware IP-to-USB bridge and switching device that connects network and USB cameras to conferencing systems through a single USB output.

No Username/Password Auth

Voice Tracking does not support username/password authentication with the INOGENI CAM230. Leave the Username and Password fields blank.

Step 1: Get the INOGENI Connection Details​

  1. Connect the INOGENI CAM230 or IP2USB to your network.
  2. Find its IP address from your network's DHCP table or the INOGENI management interface.
  3. Note the Port (default: 80) if you are using the CAM230. The IP2USB setup does not require a port number.

Step 2: Configure the Switcher Connection​

In the Voice Tracking configuration menu, click the Switcher tab and select the INOGENI CAM230 or IP2USB as the switcher type.

For a CAM230, configure:

FieldValue
Switcher TypeINOGENI CAM230
IP AddressIP address of the INOGENI CAM230
PortCommunication port (default: 80)

For an IP2USB, configure:

FieldValue
Switcher TypeINOGENI IP2USB
IP AddressIP address of the INOGENI IP2USB
Auth TokenOptional authentication token
INOGENI IP2USB

For details about obtaining and using the Auth Token, refer to the INOGENI IP2USB documentation.

Step 3: Start the Switcher​

Click Start Switcher. A success message will confirm the connection is active.

Stopping the Switcher​

To disconnect from the switcher at any time:

  • Click Stop Switcher in the Voice Tracking toolbar (the same button used to start it).
  • The switcher connection will close immediately.
  • The microphone connection remains active unless you also click Stop Microphone.

Zone-to-Source Mapping​

After the switcher is connected, map each zone to the correct switcher source:

  1. Click a zone header on the zone map.
  2. In addition to the Camera and Preset dropdowns, a Switcher Source field is available.
  3. Select the input/scene number that corresponds to the camera covering that zone.

For multi-camera setups where multiple zones share one camera, assign the same switcher source to each zone within that camera's field of view.

Troubleshooting
SymptomLikely CauseResolution
Start Switcher fails immediatelyWrong IP, port, or credentialsCheck CAM230 IP/port or IP2USB IP/token and switcher availability.
Zones activate but no cuts happenSwitcher connected but sources not mappedVerify zone-to-source assignments in the zone map.
INOGENI cuts not happeningCAM230 username/password enteredClear the CAM230 Username and Password fields.
Cuts happen with wrong cameraZone-to-source mapping incorrectRecheck zone assignments and input/scene numbers.
Switcher connects but immediately disconnectsFirewall blocking the portAllow the configured port between the camera and switcher through the firewall.

Next Steps​

With the switcher connected, return to Zone Configuration to assign switcher sources to each zone.