INOGENI
PTZOptics Voice Tracking supports two INOGENI switchers:
- INOGENI CAM230
- INOGENI IP2USB
The INOGENI CAM230 is a hardware USB/IP capture and switching device that supports a REST API for automated input switching.
The INOGENI IP2USB is a hardware IP-to-USB bridge and switching device that connects network and USB cameras to conferencing systems through a single USB output.
Voice Tracking does not support username/password authentication with the INOGENI CAM230. Leave the Username and Password fields blank.
Step 1: Get the INOGENI Connection Details
- Connect the INOGENI CAM230 or IP2USB to your network.
- Find its IP address from your network's DHCP table or the INOGENI management interface.
- Note the Port (default:
80) if you are using the CAM230. The IP2USB setup does not require a port number.
Step 2: Configure the Switcher Connection
In the Voice Tracking configuration menu, click the Switcher tab and select the INOGENI CAM230 or IP2USB as the switcher type.
For a CAM230, configure:
| Field | Value |
|---|---|
| Switcher Type | INOGENI CAM230 |
| IP Address | IP address of the INOGENI CAM230 |
| Port | Communication port (default: 80) |
For an IP2USB, configure:
| Field | Value |
|---|---|
| Switcher Type | INOGENI IP2USB |
| IP Address | IP address of the INOGENI IP2USB |
| Auth Token | Optional authentication token |
For details about obtaining and using the Auth Token, refer to the INOGENI IP2USB documentation.
Step 3: Start the Switcher
Click Start Switcher. A success message will confirm the connection is active.
Stopping the Switcher
To disconnect from the switcher at any time:
- Click Stop Switcher in the Voice Tracking toolbar (the same button used to start it).
- The switcher connection will close immediately.
- The microphone connection remains active unless you also click Stop Microphone.
Zone-to-Source Mapping
After the switcher is connected, map each zone to the correct switcher source:
- Click a zone header on the zone map.
- In addition to the Camera and Preset dropdowns, a Switcher Source field is available.
- Select the input/scene number that corresponds to the camera covering that zone.
For multi-camera setups where multiple zones share one camera, assign the same switcher source to each zone within that camera's field of view.
Troubleshooting
| Symptom | Likely Cause | Resolution |
|---|---|---|
| Start Switcher fails immediately | Wrong IP, port, or credentials | Check CAM230 IP/port or IP2USB IP/token and switcher availability. |
| Zones activate but no cuts happen | Switcher connected but sources not mapped | Verify zone-to-source assignments in the zone map. |
| INOGENI cuts not happening | CAM230 username/password entered | Clear the CAM230 Username and Password fields. |
| Cuts happen with wrong camera | Zone-to-source mapping incorrect | Recheck zone assignments and input/scene numbers. |
| Switcher connects but immediately disconnects | Firewall blocking the port | Allow the configured port between the camera and switcher through the firewall. |
Next Steps
With the switcher connected, return to Zone Configuration to assign switcher sources to each zone.