07/30/2025
SimplTrack 3 - v1.0.81
Bug Fixes
- Addressed an issue with high bandwidth and low bandwidth stream mismatch.
- Resolved an issue where NDI low bandwidth mode was not functioning on the PTZ stream.
- Corrected static fallback behavior to default to
192.168.100.88instead of192.168.1.180. - Resolved issue where some camera presets could not be overwritten.
- Fixed a bug where using the Apply button on Zone Settings (Preset Zone, Tracking Zone, or Blocking Zone) would disable any enabled Preset Zones functions.
- Resolved issue where the NDI device name would not save after reboot.
- Fixed multiple instances of the Discovery Server being referenced simultaneously.
- Corrected issue where the firmware update server could not download new firmware to the local PC.
Known Issues
- NDI low bandwidth mode does not function on the Reference Stream.
- Audio does not transmit over NDI.
- RTMP issue: If a green screen appears when using Stream 2 or 3, the user must return to Stream 1 before switching.
- Reference Lens: Image, exposure, and color settings on the Reference Lens do not save after reboot.
- When making adjustments to Exposure settings, it will not save after a reboot and revert back to Auto Exposure.
- Adjusting saturation in the Reference View affects the PTZ View instead of the intended Reference View.
- When saving a preset and renaming it, the Set button does not save the name, and pressing Enter does not save the preset. Workaround: Move the camera to the desired location, enter the preset number and press Set, then type the preset name and press Enter.
- If Zoom While Tracking is on and Track Outside Ref. View is off, the camera will continue to track outside the reference view.
- When Gesture Control is enabled, zoom may not function as expected.