Skip to main content

01/12/2026

Move SE 12X - v9.1.46Move SE 20X - v9.1.34Move SE 30X - v9.1.39

New Features​

Video and Audio Enhancements​

  • NDI 6 Upgrade: Upgraded NDI support from NDI 5 to NDI 6 for improved compatibility, performance, and access to the latest NDI protocol features.
  • NDIHX3 Support: Added support for NDIHX3. To enable, set the camera to HDMI-SDI/IP and toggle NDIHX3 to On. HX3 profiles can then be defined as needed.
  • Audio Sample Rate Support: Added support for 44.1 kHz and 48 kHz audio sample rates (previously limited to 32 kHz).
  • Resolved an RTMP issue with compatibility errors when connecting to CDNs related to frame rate, keyframe intervals, and bitrate.
  • Audio Settings Page Reorganized: Encoding and decoding settings were restructured for improved clarity and user experience. Settings are now grouped more logically to help users configure audio more efficiently.

Automation and Control​

  • Subject Switching: Added the ability to switch between tracked subjects using left/right arrows via web UI, IR remote, and VISCA joystick commands.
  • Tracking Presets: Added dedicated presets for Auto Tracking control:
Preset 150 = Tracking ON
Preset 151 = Tracking OFF
  • HTTP Movement Status Query: Added a route to allow users to query whether the camera is actively moving. The endpoint returns a boolean response indicating Pan, Tilt, Zoom, or Focus motion.
note

This status does not report focus movement when Auto Focus is enabled.

GET /api/v1/info/is-moving

Example:

GET http://192.168.100.88/api/v1/info/is-moving

Returns:

{
"isMoving": false
}

UI and Systems Changes​

  • Guest Access Controls: Guest users are now limited to appropriate routes and no longer have access to SRT or RTMP credentials.
  • Onvif Authentication Default Enabled: ONVIF authentication is now enabled by default to align with updated security protocols and ensure the ONVIF route is protected out of the box.
  • Exposure Bright Mode: Added Bright as an exposure mode option.
  • Updated Encoding Protocol Info Symbol: Added a new info icon next to the Encoding Protocol selection in the web UI. It provides descriptions of each protocol.

Bug Fixes​

  • Tracking Sensitivity: Improved tracking stability at full zoom by reducing over-sensitivity to minor subject movements.
  • Pan/Tilt/Zoom Stop Independence: VISCA Pan/Tilt stop commands no longer interrupt Zoom.
  • Home + Navigation Commands: Resolved an issue where recalling Home position followed by HTTP navigation commands caused the camera to stop zooming prematurely.
  • Relative Tilt Bug: Fixed a bug where the camera would tilt up when at the lower tilt limit and receiving a Relative Position Down command.
  • RTMP CDN Errors: Resolved frame rate, bitrate, and keyframe issues blocking some RTMP streaming. Note: When RTMP streaming to YouTube using camera video templates, bitrate errors may occur. Resolution: Adjusting the camera’s video settings to align with YouTube’s video requirements will improve streaming stability and functionality.
  • Snapshot Stability: Fixed a long-term uptime issue where snapshot images would eventually fail.
  • Time Server Application Failures: Fixed behavior where valid NTP time servers (like IPs with .100 octets or certain hostnames) failed through the Web UI but worked via HTTP.
  • NTP Fallback: Fixed a bug preventing consistent NTP server connection after boot, causing fallback to system time.
  • NTP Time Zones: Resolved an issue where certain time zones could not be set from the web UI.
  • Audio Out Menu Simplified: Removed Off option since audio disablement is handled by Audio Codec toggle.

Known Issues​

  • Cannot Set Some NTP Servers via Web UI: Some domain strings (for example, time-a-g.nist.gov) fail via Web UI but work using the HTTP API commands.
  • Time Zone Compatibility: Time zone handling may cause SSL certificate renewal failures. Ongoing adjustments are needed.
  • NTP Reboot: Changing the timezone in NTP settings requires a camera reboot.
  • Pan/Tilt Limits Not Persistent: Pan/Tilt Limits are not retained after a reboot; they reset instead of persisting after the reboot.
  • Incorrect VISCA over IP Responses: Changing the Serial VISCA address alters IP response headers (for example, 90 becomes a0, b0, and so on).
  • Pelco P/D Zoom Stop Issue: Pelco P/D Zoom and Focus Stop commands are not received, causing the camera to zoom continuously to its limit.
  • NDI Studio Monitor Hotkeys: Ctrl+Right and Ctrl+Down precision movement do not work. Other Ctrl+Arrow keys function as expected.
  • NDI HX3 Video Template Mismatch: When NDI HX3 is enabled, switching to certain video modes (for example, USB/IP/HDMI-SDI_30FPS) disables HX3 but the Video Template does not reflect the correct available options or default values.
  • NDI HX3 Video Framerate Mismatch: When NDI HX3 is enabled, the Framerate is grayed out, and may not default to 60Hz or 50Hz defined by the certification standards.
  • ONVIF Preview Image Fails: No image preview when HTTP Auth is enabled.

Ask PTZOptics AI