Skip to main content

Audio-Technica

ATND1061

The ATND1061 is a network-connected beamforming microphone array designed for professional AV installations. Both the LK and DAN variants are supported.

Connection

  1. In Voice Tracking configuration, select Audio Technica ATND1061 from the Microphone Type dropdown.
  2. Enter the microphone's IP Address.
  3. Enter the Port.
  4. Enter the Microphone Multicast IP Address.
  5. Enter the Microphone Multicast Port.
  6. Adjust the Threshold Settings as needed.
  7. Click Start Microphone.

16 Zones will populate once the microphone is started. Assign cameras and presets to each zone from the zone map.

About Threshold Settings

Threshold settings control how Voice Tracking interprets audio data from the microphone to determine when to switch zones. Adjusting these settings can help optimize tracking performance for different room acoustics and noise levels. Some microphones (like the Televic Confero and Yamaha RM-CG) do not allow adjustment of all threshold settings, but the core principles apply across all supported microphones.

ThresholdPurposeNotes
Decibel ThresholdSets the noise floor, audio below this level is ignoredIncrease in noisy rooms (HVAC, projectors)
Verification ThresholdConsecutive 100ms readings to verify a voiceDefault: 3
Identification ThresholdVerifications required before action firesDefault: 3
Silence ThresholdSeconds of silence before silence zone activatesDefault: 7 seconds
General Tips
Zone Names

Giving zones clear, descriptive names (matching your physical room areas) makes zone-to-camera assignment easier and helps you identify which zone is active at a glance on the zone map.

Port Reference

Refer to your microphone system's documentation for the default API port. For the Nureva HDL410, the port is displayed in Nureva Console under Local Integrations.